A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.

Outdoor Fan Motor -- The outdoor fan, also called the condenser fan, is exposed to external conditions. As such it is most prone to dust and debris and the extreme weather. In desert climates, the outdoor fan motor is subject to heat not only from normal operation but from the outside temperature as well. As it starts to fail, the fan may work fine in the cooler morning hours but stop by afternoon. This can shut down the entire system for hours. When they stop running completely, your air conditioner will no longer work. Running a faulty fan will lead to compressor failure, which is a very costly repair.


With colder weather on its way back to Nashville, furnace and heating repair may not be at the top of your to-do list, but maybe it should be. Sure, it’s easy for us to sit here and tell you to schedule annual furnace service, but it’s only because we want to help you avert a heating breakdown during the coldest day of the month in Nashville. Day or night, our HVAC professionals are here to make certain that you have a comfortable home, and can help get your furnace back running in little time.
Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[28]
Put simply, any home that uses air pushed through ductwork for heating purposes takes advantage of forced air heating. In other words, this term refers not to your furnace, but to the delivery method of the heat throughout your home. Forced air heating is possible with electric or gas furnaces, or a heat pump. Any issues with this delivery system that aren't directly related to the furnace likely have to do with the duct work, which costs between $35 and $55 per linear square foot to repair, or the air handling unit.
The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
For more than sixty years, Nerthling's Heating and Air Conditioning has continued a tradition of superior customer service across Erie County, including Erie, Millcreek and Fairview.  Family owned and operated, we treat you, your home, and your comfort the way we would like to be treated.  This commitment to integrity extends to every service and product we provide.  Our goal is to deliver the highest rewards for your investment, whether you require installation, maintenance, or repair.  We offer a wide range of styles and sizes of equipment, services, and resources to help you achieve your goals for temperature control, air quality, and energy savings.
Extensive training – Over the years, we have had to learn continually and update our skills to stay top-of-the-line. We continue to offer state-of-the-art products today with the service skills to match. We offer 800 hours of training classes to our technicians every year. They also have access to factory resource personnel and engineers for consultation.
The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.
Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. (Minisplit ductless systems are used in these situations.) Outside of North America, packaged systems are only used in limited applications involving large indoor space such as stadiums, theatres or exhibition halls.
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
Electronically Commutated (EC) fans use brushless DC motors which include in-built electronics to convert the AC supply to DC without the need for a separate DC supply. EC fans provide a more efficient (up to 30%) means of airflow through Precision Air Conditioning (PAC) units with the additional benefit of variable speed control via an output signal from the unit controller. Also see EC Fan upgrades.
Have your contractor do a load calculation based on a recognized method, such as one in Manual J from the ACCA. The contractor’s evaluation should include whether your ducts need to be resized, sealed and insulated, or replaced. Remember that an indoor evaporator coil and outdoor condenser must be a matched set from the same brand, or the performance, efficiency, and capacity might not meet expectations.
We maintain a complaint-free A+ rating with the Better Business Bureau, and are a 2017 Better Business Award Winner for ethics. Comfort Plus Services has achieved recognition as a Carrier Factory Authorized Dealer for sound business practices, technical expertise, and customer approval ratings. We simplify the demands of local weather and a comfortable home with upfront pricing, honest estimates, comprehensive service plans, and Emergency Service throughout Salisbury, Fruitland, Delmar, Hebron, Eden, Delmar, Parsonsburg, Pittsville, Mardela Springs, Princess Anne & Willards, MD and more. See our Areas of Service. For new home comfort systems, Comfort Plus Services protects your interests with a 100% money back guarantee. We provide expert service you can trust.
Its unique feature is the presence of one main external unit that connected to several indoor units. Such systems might be the right solution for maintaining the microclimate in several offices, shops, large living spaces. Just few of outdoor units do not worsen the aesthetic appearance of the building.The main external unit can be connected to several different indoor types: floor, ceiling, cassette, etc.

Furnace Repair

×