This may apply to a system using fresh air for cooling the space or a water cooled or glycol cooled system with an additional coil that provides chilled water cooling when the outdoor ambient is cold; thereby reducing or eliminating compressor operation. These systems may provide free cooling for up to 80% of their operating life, particularly when operating in Northerly climates. See our Free Cooling page for more information.
Air conditioner inverter Air door Air filter Air handler Air ionizer Air-mixing plenum Air purifier Air source heat pumps Automatic balancing valve Back boiler Barrier pipe Blast damper Boiler Centrifugal fan Ceramic heater Chiller Condensate pump Condenser Condensing boiler Convection heater Cooling tower Damper Dehumidifier Duct Economizer Electrostatic precipitator Evaporative cooler Evaporator Exhaust hood Expansion tank Fan coil unit Fan heater Fire damper Fireplace Fireplace insert Freeze stat Flue Freon Fume hood Furnace Furnace room Gas compressor Gas heater Gasoline heater Geothermal heat pump Grease duct Grille Ground-coupled heat exchanger Heat exchanger Heat pipe Heat pump Heating film Heating system High efficiency glandless circulating pump High-efficiency particulate air (HEPA) High pressure cut off switch Humidifier Infrared heater Inverter compressor Kerosene heater Louver Mechanical fan Mechanical room Oil heater Packaged terminal air conditioner Plenum space Pressurisation ductwork Process duct work Radiator Radiator reflector Recuperator Refrigerant Register Reversing valve Run-around coil Scroll compressor Solar chimney Solar-assisted heat pump Space heater Smoke exhaust ductwork Thermal expansion valve Thermal wheel Thermosiphon Thermostatic radiator valve Trickle vent Trombe wall Turning vanes Ultra-low particulate air (ULPA) Whole-house fan Windcatcher Wood-burning stove
Because there are so many different potential causes of indoor air quality problems, it is necessary to determine with certainty just what issues you are dealing with in your home. The only way to do so is with the assistance of a qualified professional. Once we discover the source of your IAQ problems, we can go about resolving them with the proper products and services. Call today to enjoy improved indoor air quality in Issaquah, WA.

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
Our team members are all highly-qualified and our HVAC products are the best available on the market. We want to be your first choice when you are looking for an air conditioner and heating company in Toronto. City Air Conditioning and Heating is always looking for more advanced and better ways to help serve our valued customers because we are committed to meeting all of your Toronto air conditioning and heating needs. We would love to hear from you and for you to let us know what we can do better to serve you and your needs.
As a family owned and operated full-service HVAC provider in Erie, we recognize the concerns and challenges of keeping your home and family perfectly comfortable without breaking your budget.  At Nerthling's Heating and Air Conditioning, we go above and beyond to eliminate inconvenience, protect your investment, and find solutions you can easily afford.  To better serve your needs, we offer extended regular service hours from 8 to 6 PM Monday through Saturday, available throughout Erie County, including Millcreek, PA, Erie, PA & Fairview, PA.  In emergency situations, we are always available, twenty-four hours a day, seven days a week.  Know that when you call Nerthling's Heating and Air Conditioning, we are 100% committed to your satisfaction.  We treat your home like it’s our own.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.

Turn off the gas supply valve, typically located by your gas meter on the gas inlet pipe. Turn off the gas by rotating the valve one quarter turn with an adjustable wrench. When the gas is off,  the valve’s oblong stem points perpendicular to the inlet pipe. Then call your gas utility or the fire department from a remote location. Do not return to your home until you know it is safe.

Packaged terminal air conditioner (PTAC) systems are also known as wall-split air conditioning systems.[36] They are ductless systems. PTACs, which are frequently used in hotels, have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with an opening passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas, or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning.
For most homeowners, any HVAC repair needs to be done in a timely manner. The longer you have to wait for AC repair, furnace repair, etc., the more difficult you will find it to maintain a comfortable temperature in your residence. Our experienced technicians will find the problem and complete air conditioner or furnace repair quickly. Instead of having to suffer through a cold winter or hot summer due to HVAC problems, contact Deljo Heating & Cooling.
Central heating systems have a primary heating appliance, such as a furnace, typically located in your basement or garage. All furnaces consist of four main components: 1) burners that deliver and burn fuel, 2) heat exchangers, 3) a blower and 4) a flue that acts as an exhaust for gaseous by-products. Depending on your situation, region and needs, you can choose from heating systems running on either gas or oil as fuel, or a hybrid packaged system that can use both fuel types.
Relative humidity is the ratio of the partial pressure of water vapour in an air-water mixture to the saturated vapour pressure of water at a prescribed temperature. In prevailing Northern European conditions relative humidity and percentage saturation (ration of moisture content) can be considered the same as the divergence is <1%.  In high temperature areas they should be treated differently as the divergence may be as high as 10%.
Yes. You should expect to pay a diagnostic fee to cover the cost of the technician's visit, the diagnosis of your air conditioner's problem, and a quote for the repair options. You will be advised of the issue along with recommended options to correct it, which may include a system replacement if your unit is old or significantly damaged. If you decide to replace the system, the diagnostic fee will be credited toward your replacement purchase.
×