As the system carries the cool air through the home, it becomes warmer as it travels through the system.  The air then circulates back to the central air conditioner through the return ducts and registers.  A benefit of a central air conditioner is that it helps dehumidify the incoming air but with extreme humidity, you may have to invest in a dehumidifier to help lower the moisture in the air.  There are also two different types of central air conditioners to choose from.
In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
If you find yourself having a more traditional concern, we can help with that as well. Whether you’re looking to upgrade to a more energy efficient system, require an emergency furnace repair, or need to schedule an annual appointment, we’re here to help. We can tackle any issue or concern that you may have with your HVAC system. Our team will give you confidence and peace of mind when it comes to your HVAC system.
Indoor Coil -- The indoor coil is a heat transfer device. It absorbs the heat from the inside of the house and passes it on to the refrigerant and is pumped outside. Dust that builds up on the coil can hamper its ability to absorb heat. High heat transference coils use very thin metal. Airborne chemicals can cause corrosion which leads to leaks. The constant vibration of the compressor can also cause solder joints to weaken and leak. An indoor coil may operate for weeks with a tiny leak, and you may not notice the loss in performance right away. As soon as a leak is made known, it should be replaced or repaired immediately.
Buy Home Air Conditioner - We also sell air conditioner equipment like AC condensers and heat pump condensers as well. Need a cased evaporator coil? No problem! Make sure to check out our full lines of trusted air conditioning products – and don't hesitate to contact us with any product-specific questions that may come up during the process of shopping for your new AC.
Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[28]
Your comfort is important, and our technicians at Bob’s Heating & Air Conditioning are happy to ensure that that comfort is protected throughout the entire year. That is why we offer comprehensive heating, air conditioning and water heater services in Issaquah, WA. If you need any HVAC or water heater installation, repair or maintenance services, we are the experts you can count on every time.
Nothing is worse than having your furnace fail on the coldest night of the year. When your furnace needs a repair, you shouldn’t have to worry about the company providing your furnace repair services. You won’t have to – not when you give John Betlem Heating & Cooling a call. No matter what kind of furnace you own, our talented team of technicians are able to easily identify any problem your furnace might be having.
Here’s what you should know about air handlers: if you’re searching for a conventional furnace or air conditioner, you’ll likely never need to know what an air handler is because it’s probable you won’t need one. However, if you’re in the market for an electric heat pump, it’s helpful to know that an air handler will probably be a part of your home’s HVAC system.
In a chilled water system, liquid water is pumped throughout the building to “chilled water coils”. Since the liquid water needs to be at a cold temperature, a “cooling plant” is required. The plant is typically referred to as a chiller plant. Vapor compression equipment in the plant, similar to that described in “How does my AC work”, cool water to a cold temperature and pump the cold water to air-to-water heat exchangers where needed.
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
You can adjust for seasons: During the summer, you can have the air conditioner stay off during the cooler morning hours and start cooling the house as everyone gets up and starts moving around. During the winter, you can have your heater stay off while you are away at work and turn on about a half hour or so before you get home so that you are coming home to a nice, warm house.
In variable climates, the system may include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a facility to be heated and cooled by a single piece of equipment by the same means, and with the same hardware.
We are open from 7am to 10pm every weekday and from 7am to 8pm on weekends. We book appointments in a 2 hour arrival window and call 30-45 mins before we arrive so you do not have to sit around waiting. It is often possible to schedule your appointment in the evening or morning hours to avoid conflicting with your work schedule. Are you looking for service today? Give us a call or click on one of the Schedule Service buttons found on the top and left sides of this page to contact us today.
Advantages of the ductless system include smaller size and flexibility for zoning or heating and cooling individual rooms. The inside wall space required is significantly reduced. Also, the compressor and heat exchanger can be located farther away from the inside space, rather than merely on the other side of the same unit as in a PTAC or window air conditioner. Flexible exterior hoses lead from the outside unit to the interior one(s); these are often enclosed with metal to look like common drainpipes from the roof. In addition, ductless systems offer higher efficiency, reaching above 30 SEER.[39]
An air handler contains the components that move the air throughout your home, called the blower. It is usually set inside the home and operates with both the heating and cooling components of your HVAC system. If you take a quick look at an air handler, it may closely resemble a furnace. Air handlers can run with an air conditioner and contains the indoor coil, used to cool and heat your home depending on which system it’s running with.
Check their background. Contractors who bid on your installation should show you verification of bonding and insurance, plus any required contractor’s licenses. Check with your local Better Business Bureau and consumer affairs office for complaint records. It’s a plus if technicians are certified by a trade organization, such as North American Technician Excellence or HVAC Excellence, to service residential heating and cooling equipment. Those and other similar programs assess the technician’s knowledge of specific types of equipment and their proper service methods.
Saving you money – When you have an emergency furnace repair, one concern that comes to mind is how much it will cost to repair your furnace. Many companies will charge an additional fee to come to your home in the middle of the night or on the weekend. That’s not us. We never charge an emergency fee. Keeping your repair costs affordable is of utmost importance to us.
"I was experiencing problems with one of my rooms not getting enough air flow, I was reached out to and they got a better feel for what my situation was and gave me the best honest opinion about what I should do, I really appreciate their professionalism in the manner and not just trying to gain my business. They really looked out for me as a customer, and I couldn’t be more grateful!"

Air Conditioning Parts is an international AC Parts distributor specializing in OEM wholesale A/C Parts for all air conditioner makes and models. All of our parts and equipment are available at factory direct pricing! For almost 30 years, our exceptional level of service and responsiveness coupled with our experienced air conditioning parts specialists have allowed us to establish solid long term relationships with thousands of A/C service companies, hotel and motel owners, apartment owners and management companies, and numerous other industry professionals who need and count on a knowledgeable AC parts supplier for the right part, overnight delivery and the best possible prices for all types of air conditioning parts and AC equipment. Professionals know they can depend on Air Conditioner Parts! Let us earn your trust. Call us for any A/C Part or any A/C Equipment at 800-525-3572.


Roof-mounted systems have the heating and cooling systems in one cabinet. Sometimes called "gas packs" (if the heater uses natural gas), they typically cost less than a comparable split system. In dry regions, most homes originally had "swamp-coolers" installed. When replacing them with HVAC systems, it's often cheaper to use existing mounts and ducting.
Locally owned and family operated, M and M, Heating & Cooling, Plumbing & Electrical customizes solutions to perfectly fit your requirements and lifestyle. We specialize in a wide range of services including plumbing, water heating, indoor air quality, and residential and commercial temperature control. Our team of highly trained and certified technicians are fully licensed and insured, adhere to strict service procedures, and meet exacting standards of quality. Call on M and M, Heating & Cooling, Plumbing & Electrical at (720) 443-6119 for dedicated service throughout Longmont, CO & surrounding areas, and have confidence in a rewarding experience and long-term results. With over eighteen years of satisfied customers, we take great pride in a job done right.
In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.
Split ductless systems have an outside condenser and compressor, and one to four or more indoor blower units, called air handlers, mounted high on the wall that distribute air. The indoor and outdoor sections are connected by a thin conduit that houses the power cable, refrigerant tubing, and a condensate drain. The conduit is run through about a 3-inch hole hidden behind each air handler. Each air handler cools the room in which it’s installed, and you set the temperature with a remote control. Split ductless systems can be more expensive than window air conditioners, and professional installation is recommended. While not technically central air, the cooling they provide can feel like a central air system.
Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.
For starters, once a year, vacuum out the area around the furnace’s blower. If possible, also slide out the fan unit, clean each fan blade with a toothbrush, and then vacuum with a brush attachment on a vacuum cleaner. While you’re at it, look for oil ports on the motor, normally located near the motor shaft. If the motor has these, apply two to three drops of non-detergent motor oil into each port (you may have to remove a cover plate to do this). Though most contemporary motors don’t require lubrication, do lubricate motors with oil ports once a year. For more about maintenance, see Maintenance Checklist for Central Heating Systems.
Bryant has been an industry leader of heating and cooling products for over a century. Innovative Bryant HVAC systems provide dependable solutions to home and commercial comfort and air quality. With everything from heat pumps to gas furnaces and air conditioning systems, Bryant has the products that offer leading-edge technology and precision engineering. Call us today to learn more!
For residential homes, some countries set minimum requirements for energy efficiency. In the United States, the efficiency of air conditioners is often (but not always) rated by the seasonal energy efficiency ratio (SEER). The higher the SEER rating, the more energy efficient is the air conditioner. The SEER rating is the BTU of cooling output during its normal annual usage divided by the total electric energy input in watt hours (W·h) during the same period.[33]

In a thermodynamically closed system, any power dissipated into the system that is being maintained at a set temperature (which is a standard mode of operation for modern air conditioners) requires that the rate of energy removal by the air conditioner increase. This increase has the effect that, for each unit of energy input into the system (say to power a light bulb in the closed system), the air conditioner removes that energy.[30] To do so, the air conditioner must increase its power consumption by the inverse of its "efficiency" (coefficient of performance) times the amount of power dissipated into the system. As an example, assume that inside the closed system a 100 W heating element is activated, and the air conditioner has a coefficient of performance of 200%. The air conditioner's power consumption will increase by 50 W to compensate for this, thus making the 100 W heating element cost a total of 150 W of power.


Sky Heating & Air Conditioning answers any comfort challenge with straightforward, satisfying solutions. We get rid of the need for labor-intensive renovation. We don’t tear down walls or ceilings, steal precious closet space for the installation of ductwork, or cause mess or damage. With the installation of a ductless HVAC system, we answer your temperature control requirements with wonderful simplicity.
×