As this liquid passes through the indoor cooling coil on the inside of the heat exchanger, two things happen to the air that passes over the coil’s surface on the outside of the heat exchanger. The air’s temperature is lowered (sensible cooling) and moisture in the air is removed (latent cooling) if the indoor air dew point is higher than the temperature of the coil’s surface. The total cooling (capacity) of an AC system is the sum of the sensible and latent cooling. Many factors influence the cooling capacity of a DX air conditioner. Total cooling is inversely proportional to outdoor temperature. As the outdoor temperature increases the total capacity is reduced. Air flow over the indoor cooling coil also affects the coil’s capacity and is directly proportional to the total capacity of an AC system. As air flow increases, the total capacity also increases. At higher air flow rates the latent capacity of the cooling coil is reduced. Indoor temperature and humidity also affect the total capacity of the AC system. As indoor temperatures increase, the sensible capacity also increases. Similarly, as indoor relative humidity increases the latent capacity of the AC system increases. Manufacturers of AC equipment typically provide a “performance map” of specific equipment to show how total, sensible, and latent capacity change with changing indoor and outdoor temperatures and humidity. Power consumption and energy efficiency are also provided in these charts.
Taking used gas out of a fridge system and filling it into packages. Avoids release into the environment – an action that is environmentally irresponsible and illegal in many countries. This process is usually performed by a refrigeration contractor. This occurs during maintenance or when removing a refrigerant permanently due to equipment decommissioning or retrofitting to a new gas.
Arundel Cooling has been proudly providing HVAC services in Columbia, Maryland for more than 40 years now. With this much experience, we bring our extensive knowledge and expertise to every HVAC repair or installation job we complete. No matter what time of day, Arundel Cooling and Heating will be there for you. We make ourselves available 24 hours a day, 7 days a week, so whether you need to schedule an appointment or you’re having a heating and cooling emergency, you can count on Arundel Cooling and Heating.

Keep in mind that ducts used for heating might not be the right size or in the right location for optimal cooling. Your contractor should ensure that duct sections are properly sized and that there are enough supply registers to deliver sufficient air to the right spots. Undersized ductwork can make for inefficient and noisy operation. Here’s how to keep yours humming:
The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
About us: Vredevoogd Heating & Cooling has been in business since 1964. As a financially stable company known for its reliable expertise and first-rate customer care, Vredevoogd Heating & Cooling is a company you can trust. Moreover, when you do business with a stable business like Vredevoogd Heating & Cooling, you have the peace of mind of knowing that your warranties are solidly backed by a company that intends to remain in business for another 50+ years and beyond. Don’t trust your essential home systems and investment to any fly-by-night company. Our best practices ensure that we will be here to meet our customer’s HVAC needs for decades to come. Vredevoogd Heating & Cooling founder Dennis Vredevoogd set the high standards by which the company continues to pride itself for. Today, the company continues to be family owned and operated by the founder’s sons, Michael and Thomas, who are committed to maintaining the company’s high standards and complementing them with the innovative technical know-how needed to service today’s advanced HVAC systems.
Indoor Fan Motor -- Indoor fans circulate the air from your house and through the system. Age and dust buildup are the two biggest contributing factors to their failure. When they are starting to fail they will often make noise. Failure of the fan will result in no heating or cooling, and if it is not repaired soon, it can cause other components to fail.
Given the broad price ranges above, it's easy to recognize that the cost of your furnace repair varies drastically based on which parts need attention. As a result, it makes sense to gain a better understanding of the parts that heat your home, and how much they cost to repair. Repairing or replacing your furnace’s blower motor can cost you anywhere between $150 and $450, depending on the extent of the damage. Heat exchanger repair costs can vary greatly, from as little as $100 for a simple fix to as much as $1,200 for a full replacement. Repairing a furnace igniter will only cost you $300 at most, while flame sensor repairs generally fall between $80 to $250. The average cost to repair your Thermostat will range from $108 to $282.
Since the 1980s, manufacturers of HVAC equipment have been making an effort to make the systems they manufacture more efficient. This was originally driven by rising energy costs, and has more recently been driven by increased awareness of environmental issues. Additionally, improvements to the HVAC system efficiency can also help increase occupant health and productivity.[21] In the US, the EPA has imposed tighter restrictions over the years. There are several methods for making HVAC systems more efficient.

Heat pumps are similar to cooling only systems with one exception. A special valve in the refrigeration piping allow the refrigeration cycle to be operated in reverse. A cooling only system cools the indoor air and rejects heat to the outdoors. A heat pump can also cool the indoor air, but when the valve is reversed, the indoor air is heated. A supplementary electric resistance heater may also be used to assist the heat pump at lower outdoor temperatures. In colder climates, heat pumps require a defrost period. During defrost times the electric heater is the only means of heating the interior of the building. These units are manufactured as either split or packaged systems.


In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.