Inside the unit, the air passes over the evaporator coil first, and is cooled and dehumidified. The now dehumidified, cold air then passes over the condenser coil where it is warmed up again. Then the air is released back into the room. The unit produces warm, dehumidified air and can usually be placed freely in the environment (room) that is to be conditioned.
By combining immediate results with sustainable performance, we protect the value of your investment.  We provide skilled installation, maintenance, and repair of gas furnaces, heat pumps, dual fuel systems, boilers, air conditioners, air quality products, traditional and tankless water heaters, and advanced duct cleaning services.  Welzig Heating & Air is the right choice for  the comfort, safety, and health of homes or offices across Boulder, Longmont, Louisville, Lafayette, CO & more.
If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.

Cleaning the debris that builds up on your filters will aid with the flow of air. When your air filter is clogged, your air handler must work harder to compensate for the blockage of air flow. In addition to driving up your utility bill, the reduced air flow through your heating and cooling system can cause your heat exchanger to overheat and shut off too quickly.    
It's quite possible that you need a new HVAC unit, but we can't tell for certain. We will need to do a complete inspection of the property and conditions the unit is in. Because of the multiple maintenance aspects regarding HVAC units that could and will prevent the unit's proper functions. We are the experts in diagnostics and repairs. If your HVAC unit is at all salvageable... before we are done we'll make sure that it operates in peak condition.
©2018 By Horizon Services, LLC. All Rights Reserved. DE License # PL0000726, HL0000299. Contractor Reg. # PA017876, PA057742. NJ Plumbing Lic. # PL36BI01232300 - David Geiger HIC reg. # 13VH05117300, NJ Master HVACR contractor Lic. # 19HC00193700. MD Master HVACR contractor Lic. # 47186, MD Master Plumber/Gas Fitter Lic. # 63739 – David Geiger. EL.LIC./B.P. #34EI01207700.
A gas that can be retrofitted into a refrigeration system designed for another, without major system changes. For example, R422D is a drop-in replacement for R22 in many applications. However, hydrocarbon refrigerants are NOT drop-in alternatives for most fluorocarbon refrigerants due to substantial system changes needed to manage their differing characteristics (e.g. flammability).
A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
R407C is a zeotropic hydro-fluoro-carbon refrigerant and is a blend of difluoromethane (R32) providing the heat capacity, pentafluoroethane (R125) decreasing flammability and tetrafluoroethane (R134a) to reduce pressure. Difluoromethane serves to, pentafluoroethane andtetrafluoroethane. R407C was developed as a replacement for the ozone depleting R22.
When your heating and cooling system stops working, you need the help of a reliable, experienced, local service professional that can diagnose the problem and repair your air conditioner or furnace at a fair price. You can count on The Home Depot's licensed and insured heating and cooling professionals for all your heaters, air conditioning units, and any ventilation needs.
Filtration systems -- A second-stage filter is sometimes inserted & used to remove particulates such as pets, smoking or cooking, as well as other odors, gases, and VOCs (volatile organic compounds). A HEPA filter is also available to remove spores, pollens, bacteria and lung-damaging particles. There are also systems that use ultraviolet (UV) light to protect against bacteria and germs.
Air conditioning (often referred to as AC, A/C, or air con)[1] is the process of removing heat and moisture from the interior of an occupied space, to improve the comfort of occupants. Air conditioning can be used in both domestic and commercial environments. This process is most commonly used to achieve a more comfortable interior environment, typically for humans and animals; however, air conditioning is also used to cool/dehumidify rooms filled with heat-producing electronic devices, such as computer servers, power amplifiers, and even to display and store some delicate products, such as artwork.

Sometimes a heating and air conditioning system just needs to be repaired rather than completely replaced. You may need air conditioning repair services if there is leaking around the outside unit, the air coming into the house isn't hot or cool enough, the unit is short-cycling or constantly turning on and off, using the system is consistently resulting in higher-than-normal energy bills, or if there is excessive noise during startup and operation.

×