The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
We’ve lived our entire lives, and continue to work in Southern Maryland and parts of Virginia, and are committed to the local community. Both the loyalty of our long-term customers and our A+ BBB rating are a testament to our dedication. Exceeding your expectations for service and performance, T. N. Bowes Heating & Air Conditioning, Inc. delivers the results you’re looking for.

Relax—ABC Plumbing, Heating, Cooling & Electric is here for you when you need us most! Our highly trained, background-checked technicians perform heating and air conditioning repairs quickly and efficiently to keep your family warm and cozy all winter long. With over 65 years of experience, you can trust that we’ll fix your furnace correctly the first time.
In a chilled water system, liquid water is pumped throughout the building to “chilled water coils”. Since the liquid water needs to be at a cold temperature, a “cooling plant” is required. The plant is typically referred to as a chiller plant. Vapor compression equipment in the plant, similar to that described in “How does my AC work”, cool water to a cold temperature and pump the cold water to air-to-water heat exchangers where needed.
If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.
Inside the unit, the air passes over the evaporator coil first, and is cooled and dehumidified. The now dehumidified, cold air then passes over the condenser coil where it is warmed up again. Then the air is released back into the room. The unit produces warm, dehumidified air and can usually be placed freely in the environment (room) that is to be conditioned.

We came home to a gas leak and our CO detector going off last Thursday (was very cold out)! After contacting Natl Fuel we proceeded to call Nerthlings for help! They arrived quickly, found the problem & worked with us to install our new furnace the next day. They were great to deal with & a huge help with the bad weather we were having at the time!
In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.
Appliance Repair in Fayetteville Appliance Repair Santa Barbara Lansing, MI Appliance Repair Augusta, GA Appliance Repair Appliance Store Raleigh York Appliance Repair Appliance Repair Austin Appliance Repair Topeka Appliance Repair Louisville Appliance Repair Salem, NH Paducah, KY Appliance Repair Evansville Appliance Repair Toms River, NJ Appliance Repair Appliance Repair in Easton, PA
If you have a heating or cooling emergency, call Vredevoogd Heating & Cooling Grand Rapids MI, Furnace Repair Lansing, Furnace Repair Kalamazoo and more at 616-828-5411. When you call you speak directly with one of our service representatives about the problem you are experiencing and schedule a service appointment. Naturally, we prioritize emergencies so you can count on us when your heating or cooling systems fail. After regular business hours, you can reach our customer service staff who will report your problem to on-call technicians. You can expect to hear back from a certified tech within 15 minutes of your call. Your heating and cooling emergency is important to us. We will visit your home ASAP to provide you with the superior service you’d expect from a Furnace Repair, Air Conditioning, AC Repair & HVAC leader like Vredevoogd Heating & Cooling Grand Rapids, AC Repair Lansing, AC Repair Kalamazoo.
The main purpose of your furnace filter is to ensure that none of the additional materials your fans pull back into the unit - such as hair and dust - actually damage the furnace or its parts. In the process, it also improves air quality in your home. Some annual inspections will include changing and cleaning this part of the unit. That said, you can also clean or change your furnace filteryourself. Costs for new filters range based on brand, but tend to be around $30.
An air conditioner cools and dehumidifies the air as is passes over a cold coil surface. The indoor coil is an air-to-liquid heat exchanger with rows of tubes that pass the liquid through the coil. Finned surfaces connected to these tubes increase the overall surface area of the cold surface thereby increasing the heat transfer characteristics between the air passing over the coil and liquid passing through the coil. The type of liquid used depends on the system selected. Direct-expansion (DX) equipment uses refrigerant as the liquid medium. Chilled-water (CW) can also be used as a liquid medium. When the required temperature of a chilled water system is near the freezing point of water, freeze protection is added in the form of glycols or salts. Regardless of the liquid medium used, the liquid is delivered to the cooling coil at a cold temperature.
"I was experiencing problems with one of my rooms not getting enough air flow, I was reached out to and they got a better feel for what my situation was and gave me the best honest opinion about what I should do, I really appreciate their professionalism in the manner and not just trying to gain my business. They really looked out for me as a customer, and I couldn’t be more grateful!"
If you find yourself with a need today, don’t hesitate to contact us now. We want to prove to you why we have such stellar ratings for quality and customer satisfaction in Cary. To easily make an appointment, you can contact us on our website, chat online, or call us at 919-578-4329. With one conversation, we’ll show you why you can be comfortable and confident in your decision to work with us. Find out today what your friends and neighbors in Cary have already found: You can rely on Service Experts.

A number of other variables can influence your decision on whether to repair or replace your furnace, as well. In addition to cost and brand, consider the expected lifetime of your furnace. If it is more than 15 years old, it might make more sense to invest in a new unit even if it costs more than simply repairing the current problem. Long-term costs also play into the equation. For example, your new furnace may be more energy efficient than the current unit. Even though you will pay more for the actual installation, you might be able to make back your investment through lower energy bills. To make your decision, consult with a reliable professional on what to do. In inspecting your furnace, they will be able to make an informed recommendation that looks not just to the next year, but years into the future. That way, you can make the best possible decision for your home and budget long-term.
The thermocouple is a copper rod that the pilot flame heats-up. When it gets hot enough, the thermocouple signals that there is enough heat to burn the gas fuel being released into the appliance—and so it allows the gas to be released to the burners. In some cases where the pilot light won’t stay lit, the thermocouple needs to be adjusted or replaced. This is generally a job for a professional.
In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.

Heating Repair

×