A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.
Packaged terminal heat pumps (PTHP) are are similar to a window-mounted air conditioner. These units are typically installed in a sleeve passing through the outdoor wall of an apartment, hotel, school classroom, etc. PTHPs are completely self contained and require only an electrical connection in addition to the opening in the building shell. They use the outdoor air as the heat source in winter and as a heat sink in summer. They also can provide ventilation air. Flexibility and lower installed cost are the primary advantages of the PTHP. Disadvantages include in-room maintenance, higher operating cost, relatively short life, imprecise "on-off" temperature control, and they can be rather noisy.
In a chilled water system, liquid water is pumped throughout the building to “chilled water coils”. Since the liquid water needs to be at a cold temperature, a “cooling plant” is required. The plant is typically referred to as a chiller plant. Vapor compression equipment in the plant, similar to that described in “How does my AC work”, cool water to a cold temperature and pump the cold water to air-to-water heat exchangers where needed.
Beware these aluminum clad wood doors. The wood is particle board. Why would anyone make a storm door out of particle board? They don't seal it in any way, it gets wet between the aluminum cladding and boils and blisters the aluminum and looks terrible in just a few years. I have two Larson's and they were horrible doors almost from the start. I've seen reviews and EMCO is the exact same way. When your storm door needs a storm door, you bought the wrong door.

Air Blue Heating and Cooling Inc. protects your safety and investment with unwavering dedication.  We are available 24 hours a day, 365 days a year, for reliable Emergency Service, and as a local company we respond quickly to any crisis anywhere in Chicagoland and the surrounding suburbs, including Wheeling, Buffalo Grove, Northbrook, Deerfield, IL.  Our trucks are fully stocked with leading-edge diagnostic equipment, specialized tools, and genuine factory authorized parts to accurately identify and resolve even complex problems without delay.  We recognize the importance of a properly operating heating and cooling system to both your home and commercial facility, and never leave you waiting for a tardy technician or distant appointment time.  By offering same day service and installation, courteous customer service, and affordable pricing, we strive to make your life easier.
Air conditioner inverter Air door Air filter Air handler Air ionizer Air-mixing plenum Air purifier Air source heat pumps Automatic balancing valve Back boiler Barrier pipe Blast damper Boiler Centrifugal fan Ceramic heater Chiller Condensate pump Condenser Condensing boiler Convection heater Cooling tower Damper Dehumidifier Duct Economizer Electrostatic precipitator Evaporative cooler Evaporator Exhaust hood Expansion tank Fan coil unit Fan heater Fire damper Fireplace Fireplace insert Freeze stat Flue Freon Fume hood Furnace Furnace room Gas compressor Gas heater Gasoline heater Geothermal heat pump Grease duct Grille Ground-coupled heat exchanger Heat exchanger Heat pipe Heat pump Heating film Heating system High efficiency glandless circulating pump High-efficiency particulate air (HEPA) High pressure cut off switch Humidifier Infrared heater Inverter compressor Kerosene heater Louver Mechanical fan Mechanical room Oil heater Packaged terminal air conditioner Plenum space Pressurisation ductwork Process duct work Radiator Radiator reflector Recuperator Refrigerant Register Reversing valve Run-around coil Scroll compressor Solar chimney Solar-assisted heat pump Space heater Smoke exhaust ductwork Thermal expansion valve Thermal wheel Thermosiphon Thermostatic radiator valve Trickle vent Trombe wall Turning vanes Ultra-low particulate air (ULPA) Whole-house fan Windcatcher Wood-burning stove
One service an HVAC contractor can provide is a diagnostic test of your heating and central air unit. A reputable technician will examine your unit and ask you questions about various aspects of the system. He or she will check your furnace as well as ductwork and discuss options with you. Beware of a contractor that takes a quick look through your home or place of business and immediately tells you replacing your HVAC system is necessary.
Acosta Heating & Cooling is your one-stop-shop for all of your indoor comfort needs. We’ve been serving the Charlotte area for over 45 years, and our customers are always treated with respect and professionalism. But with so many air conditioning and heating companies out there, how are you supposed to choose? It all starts with how a company treats their customers. Here at Acosta Heating & Cooling, you’ll always be treated like family. From a quick furnace repair to comprehensive air conditioning service, Acosta will always deliver. See below for some reasons why we’re the best air conditioning and heating service company in Charlotte and surrounding areas:
The installation and maintenance specialists from Nerthling's Heating and Air Conditioning are accredited by the manufacturer, having been extensively trained to correctly size and install ductless systems.  We are uniquely qualified to recommend, design, and service state-of-the-art systems.  Through knowledgeable and accurate workmanship, you’re ensured the highest level of rewards from your ductless system.

Another HVAC system used for central heating is the heat pump. A heat pump is a single unit that provides both heating and cooling. Heat pumps can be split or packaged. If the unit is split, that means the evaporator coil is housed in a cabinet inside of your house, while the rest of the unit is in a separate cabinet outside. On the other hand, with a packaged unit the entire heat pump is housed in a metal cabinet outside.
SEER is useful for comparing one model to another much in the same way that a car's calculate MPG is useful. It's not an accurate prediction of exactly how efficient the system is, but it can tell you which one is more efficient. Also, since SEER is based on a "cooling season", what region you live in will determine how long or short your cooling season is.
Air Conditioning Your home's air conditioner is an essential part of your overall indoor comfort. A properly working system can mean the difference between a cool, comfortable summer and a hot, miserable few months. If you're currently dealing with a broken air conditioner, an inefficient system, or you would like to schedule a routine, pre-season tune-up, Horizon Services is here to help!

Furnace Repair Co

×