Indoor Coil -- The indoor coil is a heat transfer device. It absorbs the heat from the inside of the house and passes it on to the refrigerant and is pumped outside. Dust that builds up on the coil can hamper its ability to absorb heat. High heat transference coils use very thin metal. Airborne chemicals can cause corrosion which leads to leaks. The constant vibration of the compressor can also cause solder joints to weaken and leak. An indoor coil may operate for weeks with a tiny leak, and you may not notice the loss in performance right away. As soon as a leak is made known, it should be replaced or repaired immediately.
The installation and maintenance specialists from Nerthling's Heating and Air Conditioning are accredited by the manufacturer, having been extensively trained to correctly size and install ductless systems.  We are uniquely qualified to recommend, design, and service state-of-the-art systems.  Through knowledgeable and accurate workmanship, you’re ensured the highest level of rewards from your ductless system.
We came home to a gas leak and our CO detector going off last Thursday (was very cold out)! After contacting Natl Fuel we proceeded to call Nerthlings for help! They arrived quickly, found the problem & worked with us to install our new furnace the next day. They were great to deal with & a huge help with the bad weather we were having at the time!
Capacitors -- Capacitors help your HVAC motor start from a standstill. Over time they can weaken. As they weaken, they cause the motor to run hotter. This can shorten the life expectancy of your motor. Once a capacitor fails, the whole motor will stop working. You usually won't notice that a capacitor has weakened until your motor stops turning on.
Poorly maintained water cooling towers can promote the growth and spread of microorganisms,[55] such as Legionella pneumophila, the infectious agent responsible for Legionnaires' disease, or thermophilic actinomycetes. As long as the cooling tower is kept clean (usually by means of a chlorine treatment), these health hazards can be avoided or reduced. Excessive air conditioning can have a negative effect on skin, causing it to dry out, and can also cause dehydration.[citation needed]

Call us today at (302) 200-4266 today to schedule a service heating system repair, replacement, installation, or tune-up services with our capable team! our team! We offer honest, upfront pricing in writing and industry leading warranties on parts and service. Find your local Horizon today to schedule heating system repair, replacement, installation, or tune-up services with our capable team!
If your furnace has a pilot light, look for the flame. Check your owner’s manual or the instructions posted inside the furnace cabinet for step-by-step lighting instructions. Usually this involves first turning the gas valve to Off and waiting a couple of minutes. Then you turn it to Pilot. Next, press and hold it down while you light the flame. Last, wait a minute or so, release it, and then turn it to On.
In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.
This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.
Beware these aluminum clad wood doors. The wood is particle board. Why would anyone make a storm door out of particle board? They don't seal it in any way, it gets wet between the aluminum cladding and boils and blisters the aluminum and looks terrible in just a few years. I have two Larson's and they were horrible doors almost from the start. I've seen reviews and EMCO is the exact same way. When your storm door needs a storm door, you bought the wrong door.

HVAC Repair Co

×