Packaged terminal air conditioner (PTAC) systems are also known as wall-split air conditioning systems.[36] They are ductless systems. PTACs, which are frequently used in hotels, have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with an opening passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas, or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning.
As a Leesburg and Ashburn AC repair company, we offer emergency and routine AC repair services to the residents and commercial companies in Leesburg and Ashburn, Virginia. We're professional, prompt and punctual. Please call us immediately for your your repair needs. Operators are standing by to take your call. We also encourage you to read our reviews on our Google page.
We maintain a complaint-free A+ rating with the Better Business Bureau, and are a 2017 Better Business Award Winner for ethics. Comfort Plus Services has achieved recognition as a Carrier Factory Authorized Dealer for sound business practices, technical expertise, and customer approval ratings. We simplify the demands of local weather and a comfortable home with upfront pricing, honest estimates, comprehensive service plans, and Emergency Service throughout Salisbury, Fruitland, Delmar, Hebron, Eden, Delmar, Parsonsburg, Pittsville, Mardela Springs, Princess Anne & Willards, MD and more. See our Areas of Service. For new home comfort systems, Comfort Plus Services protects your interests with a 100% money back guarantee. We provide expert service you can trust.

Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.

To clean your air conditioner drain, first shut off the power to your unit at both the thermostat and the breaker. Then remove the drain pan. If the pan is full of water, soak up the liquid with a few towels or rags or use a wet vacuum. You can use a solution of water and distilled vinegar, or substitute peroxide for the vinegar, to clean out the drain pipe. Let the pipe sit for a while in the solution and then put all the parts back in place. Once you start using your air conditioner on a regular basis, check it periodically to ensure condensation isn't building up.


We live in a recently completed townhouse that was built with double-wall construction. That construction method was touted by the builder as what would keep sound from penetrating between the units. But we can hear the next door neighbors' TV and stereo, and sometimes voices and even snoring, through the wall. While sometimes it's the volume, mostly it's the bass sounds coming through the wall. They say they don't hear us, but we keep our bass turned down. They crank up the bass, and they are not going to change that. They also are not going to do anything construction-wise to help from their side. What is the best way for us to try to block the low frequency/bass sounds from penetrating the existing wall into our side?
A true central air-conditioning system uses ducts to distribute cooled air throughout the house. In a “split system,” the most common design, refrigerant circulates between an indoor coil and a matching—meaning from the same brand—outdoor condenser with compressor (see illustration, below). The refrigerant cools the air, dehumidifying it in the process; a blower circulates air through ducts throughout the house. A thermostat maintains the temperature at the setting you select. A variation is the “heat pump,” a type of system that functions as heater and air conditioner.
With the split system, the evaporator coil is connected to a remote condenser unit using refrigerant piping between an indoor and outdoor unit instead of ducting air directly from the outdoor unit. Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct handle air from the indoor unit to vents or diffusers around the rooms.
Since 1994, Welzig Heating & Air has been providing professional air quality solutions throughout Boulder, Longmont, Louisville, Lafayette, CO & more. We specialize in industry leading products and employ skilled and knowledgeable technicians to do the job right the first time. As a family owned company, we understand how important the quality of your indoor environment can be on your health, comfort, and productivity. When you call the team from Welzig Heating & Air, you’ll enjoy helpful recommendations, convenient appointment times, and rewarding installation service that leaves you feeling refreshed.
If you find yourself with a need today, don’t hesitate to contact us now. We want to prove to you why we have such stellar ratings for quality and customer satisfaction in Cary. To easily make an appointment, you can contact us on our website, chat online, or call us at 919-578-4329. With one conversation, we’ll show you why you can be comfortable and confident in your decision to work with us. Find out today what your friends and neighbors in Cary have already found: You can rely on Service Experts.
As the system carries the cool air through the home, it becomes warmer as it travels through the system.  The air then circulates back to the central air conditioner through the return ducts and registers.  A benefit of a central air conditioner is that it helps dehumidify the incoming air but with extreme humidity, you may have to invest in a dehumidifier to help lower the moisture in the air.  There are also two different types of central air conditioners to choose from.
At Air Condition Parts we know our customers! Every day we help Nursing Homes, Hotels and Motels, Hospitals, Colleges and Universities locate quality PTAC Air Conditioners and PTAC Air Conditioner Parts. These industries choose us because they have grown accustomed to our extensive experience and ability to identify and find not only today’s current air conditioner parts but those hard to locate PTAC parts, and to provide them at very competitive prices!

In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.
In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather. An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The temperature of the incoming air is reduced, but it is also more humid, so the total heat (sensible heat plus latent heat) is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite substantial.
With the split system, the evaporator coil is connected to a remote condenser unit using refrigerant piping between an indoor and outdoor unit instead of ducting air directly from the outdoor unit. Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct handle air from the indoor unit to vents or diffusers around the rooms.
We are service professionals! As licensed contractors and specialists in the field of heating and air conditioning, we have the tools, the equipment, and the experience to keep your equipment running smoothly all year long. If it is emergency service that you need we are available to assist you! To help reduce service emergencies, we offer service agreements to keep your comfort system running at peak performance.
Arundel Cooling has been proudly providing HVAC services in Columbia, Maryland for more than 40 years now. With this much experience, we bring our extensive knowledge and expertise to every HVAC repair or installation job we complete. No matter what time of day, Arundel Cooling and Heating will be there for you. We make ourselves available 24 hours a day, 7 days a week, so whether you need to schedule an appointment or you’re having a heating and cooling emergency, you can count on Arundel Cooling and Heating.
Ultimately, the cost to repair your furnace depends on a wide range of variables. From the brand of the units to the damaged or broken parts, you need a reliable and trusted professional who can evaluate the issue and recommend next steps. If you're unsure whether to repair or replace your furnace, or even where to begin, connect with a local furnace repair professional who can make sure that your home heats well both now and in the future.
Roof-mounted systems have the heating and cooling systems in one cabinet. Sometimes called "gas packs" (if the heater uses natural gas), they typically cost less than a comparable split system. In dry regions, most homes originally had "swamp-coolers" installed. When replacing them with HVAC systems, it's often cheaper to use existing mounts and ducting.
Its unique feature is the presence of one main external unit that connected to several indoor units. Such systems might be the right solution for maintaining the microclimate in several offices, shops, large living spaces. Just few of outdoor units do not worsen the aesthetic appearance of the building.The main external unit can be connected to several different indoor types: floor, ceiling, cassette, etc.

Furnace Repair

×