Nytech Heating and Cooling, is a Colorado CO Heating, Cooling, Air Conditioning, Heat Pump, Ductless Mini-Split, Furnace repair, service, replacement and maintenance Company located in Douglas County. Nytech Heating and Cooling employs only the best technician for air conditioner repair and furnace repair, as well as all air conditioner replacement, furnace replacement and boiler replacement in Castle Rock CO, Castle Pines CO, Centennial CO, Elbert CO, Elizabeth CO, Englewood CO, Franktown CO, Greenwood Village CO, Highland Ranch CO, Larkspur CO, Littleton CO, Louviers CO, Lone Tree CO, Parker CO, and Sedalia CO. So when you ask to find "A good heating and air conditioning repair or service company near me," you've come to the right place. To set-up a repair service estimate or replacement estimate, call 303-663-6840. Nytech Heating and Cooling services all furnace, AC, humidifier, filter, thermostat and water heater brands including Carrier, Bryant, Payne, Trane, Lennox, Rheem, Ruud, Amana, Daikin, Mitsubishi, Fujitsu, Crown, Frigidaire, Gibson, Goodman, Maytag, Weil McLain, A O Smith, American Standard, General, Aprilaire, Honeywell, and White Rodgers.
"LIFESAVER! Came right out to our home to save us from the heat. I called around 11 and they sent someone by the afternoon 1:30. Carlos fixed our AC on the spot! Very professional and knew what the issues were and fixed them all as fast as possible! Otherwise we would all be toast in this Texas Summer HEat. Thank you Carlos with Ruben's AC! Excellent service"
Over the Labor Day weekend our hot water heater decided it was time to say good bye. Since we had our fall check the week before, we called Nerthlings. I cannot say enough good things about how this situation was handled. The technician, Dwain, was knowledgeable, friendly, and quite helpful without being pushy. Our questions were answered clearly. I am never made to feel that this is something...
The Rack Cooling Index (RCI) is a metric that measures the percentage of racks in the data centre where the air inlet temperature is at the recommended or allowable level under the guidelines put forth by ASHRAE. RCI (hi) is the metric for racks at the upper limit and RCI (lo) for racks at the lower limit. This metric reveals how uniformly and efficiently a data centre is being cooled.
Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.
Yes. You should expect to pay a diagnostic fee to cover the cost of the technician's visit, the diagnosis of your air conditioner's problem, and a quote for the repair options. You will be advised of the issue along with recommended options to correct it, which may include a system replacement if your unit is old or significantly damaged. If you decide to replace the system, the diagnostic fee will be credited toward your replacement purchase.
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.

We take great pride in our crew, choosing the best and brightest to represent R.S. Andrews in the face of an emergency. Our HVAC contractors boast not only unparalleled skill but also a friendly and professional demeanor. All of our work comes completely guaranteed, and we won’t rest until your emergency has been resolved to your full satisfaction!
The performance of vapor compression refrigeration cycles[24] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[25]
"I was experiencing problems with one of my rooms not getting enough air flow, I was reached out to and they got a better feel for what my situation was and gave me the best honest opinion about what I should do, I really appreciate their professionalism in the manner and not just trying to gain my business. They really looked out for me as a customer, and I couldn’t be more grateful!"
Capacitors -- Capacitors help your HVAC motor start from a standstill. Over time they can weaken. As they weaken, they cause the motor to run hotter. This can shorten the life expectancy of your motor. Once a capacitor fails, the whole motor will stop working. You usually won't notice that a capacitor has weakened until your motor stops turning on.

For more than 30 years, Northeastern PA homeowners have trusted T.E. Spall & Son for heating, air conditioning, and plumbing in Scranton, Wilkes-Barre, and the surrounding areas. Our team of highly trained, professional HVAC contractors and plumbers is committed to providing you with the best heating and cooling services possible. Your satisfaction and comfort are always our number one priorities!
The 2nd-century Chinese mechanical engineer and inventor Ding Huan of the Han Dynasty invented a rotary fan for air conditioning, with seven wheels 3 m (10 ft) in diameter and manually powered by prisoners of the time.[6] In 747, Emperor Xuanzong (r. 712–762) of the Tang Dynasty (618–907) had the Cool Hall (Liang Dian 涼殿) built in the imperial palace, which the Tang Yulin describes as having water-powered fan wheels for air conditioning as well as rising jet streams of water from fountains. During the subsequent Song Dynasty (960–1279), written sources mentioned the air conditioning rotary fan as even more widely used.[7]
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
These factors are included in a "Manual J" calculation. Contractors who make these calculations before recommending a size can take a couple of hours collecting the information and making the calculation. If your contractor doesn't do it, there are services that will do it for around $99. If you're feeling particularly on the ball, there are also free online calculators.

An air conditioner's compressor contains a refrigerant. As it works, it sends this refrigerant through the system. As warm air blows across the coil that carries this refrigerant, the heat transfers to the refrigerant (cool always absorbs warm). A fan moves the cooled air through the ducting and out of vents that lead into the rooms of your house. The refrigerant returns to the compressor where the absorbed heat is moved outside. The refrigerant is then sent through the coil once again to continue the cycle.

HVAC Repair

×