The warm air inside your home is drawn into the system through return ducts and then go over a refrigerant coil. As the warm air is blown across the cooled coil, heat is removed. Refrigerant lines then carry the heat outside. Now you’re left with cool, comfortable indoor air that you can enjoy on the hottest of days. And that’s pretty much it. Sure, the equipment is more complex than that, but the process itself is easy to break down and comprehend.
Arundel Cooling has been proudly providing HVAC services in Columbia, Maryland for more than 40 years now. With this much experience, we bring our extensive knowledge and expertise to every HVAC repair or installation job we complete. No matter what time of day, Arundel Cooling and Heating will be there for you. We make ourselves available 24 hours a day, 7 days a week, so whether you need to schedule an appointment or you’re having a heating and cooling emergency, you can count on Arundel Cooling and Heating.
Packaged central air conditioner – the name is a good indicator of what to expect from a packaged central air conditioner. The evaporator, compressor, and condenser are all installed in one cabinet.  This cabinet is typically placed on a roof or a concrete slab near the house’s foundation.  Packaged ones normally include electric heating coils or a natural gas furnace, which eliminates the need for a separate furnace inside.
A little simple math can help determine the size system you need. A rule of thumb is 20 BTUs per square foot. So, a 500 square foot room would need 10,000 BTUs to cool or warm it efficiently. This assumes that you live in a temperate region and have adequate insulation with no energy loss. In the real world, all units have some degree of energy loss. This is reflected in an HVAC system's SEER rating for cooling and AFUE rating for heating.
Air conditioners contain the condenser and are traditionally set outside the home. One of the most common confusions with air conditioners is that they cool the existing air in your home. Air conditioners actually pull out heat from inside your home through a host of pieces in your system and expel it outside. The removal of heat is what makes the air feel cool, not the addition of cold air.
As the first Carrier Factory Authorized Dealer in the area, Nerthling's Heating and Air Conditioning is recognized for exemplary business practices, customer loyalty, and industry knowledge.  Our service team continues factory training, staying updated with ever-evolving techniques and technology.  We remain current with product development, qualifying us to identify equipment that accurately suits your needs and allows for maximum efficiency.  We install proven reliable systems with a track record of durability, in a variety of configurations, guaranteeing an ideal match to your expectations.  We specialize in the installation, service, and repair of air conditioning, heat pumps, furnaces, boilers, geothermal options, generators, air quality solutions, and ductless HVAC.
Window unit air conditioners are installed in an open window. The interior air is cooled as a fan blows it over the evaporator. On the exterior the heat drawn from the interior is dissipated into the environment as a second fan blows outside air over the condenser. A large house or building may have several such units, allowing each room to be cooled separately.
In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather. An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The temperature of the incoming air is reduced, but it is also more humid, so the total heat (sensible heat plus latent heat) is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite substantial.
Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation
Filtration systems -- A second-stage filter is sometimes inserted & used to remove particulates such as pets, smoking or cooking, as well as other odors, gases, and VOCs (volatile organic compounds). A HEPA filter is also available to remove spores, pollens, bacteria and lung-damaging particles. There are also systems that use ultraviolet (UV) light to protect against bacteria and germs.
Air Handling Unit (AHU): a device used to condition and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU.
Air Handling Unit (AHU): a device used to condition and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU.
Vredevoogd Heating & Cooling Grand Rapids employs more than 80 people who are proud to work under the Vredevoogd Heating & Cooling banner. Each team member shares our company values for service excellence. All of our employees are intensely screened and background checked so that you have peace of mind when they enter your home. Moreover, our technicians are certified to work in the HVAC industry and provide the level of expertise that our customers expect from Vredevoogd Heating & Cooling. We back our technicians’ work and continue to make training a priority so that all of our techs are familiar with the latest HVAC models and advances. Our customers deserve the best, so the best is what we deliver to each and every job.

When we’re in a customer’s home, we’re always on the lookout for things we can do to help them out and put a smile on their face. It could be as simple as changing a lightbulb or as involved as cleaning gutters, listing a car for sale online, or repairing a broken gate. There’s no limit to what we might do, and of course, there’s never any charge to help out. It’s good deeds for FREE!

Another HVAC system used for central heating is the heat pump. A heat pump is a single unit that provides both heating and cooling. Heat pumps can be split or packaged. If the unit is split, that means the evaporator coil is housed in a cabinet inside of your house, while the rest of the unit is in a separate cabinet outside. On the other hand, with a packaged unit the entire heat pump is housed in a metal cabinet outside.

For starters, once a year, vacuum out the area around the furnace’s blower. If possible, also slide out the fan unit, clean each fan blade with a toothbrush, and then vacuum with a brush attachment on a vacuum cleaner. While you’re at it, look for oil ports on the motor, normally located near the motor shaft. If the motor has these, apply two to three drops of non-detergent motor oil into each port (you may have to remove a cover plate to do this). Though most contemporary motors don’t require lubrication, do lubricate motors with oil ports once a year. For more about maintenance, see Maintenance Checklist for Central Heating Systems.


As a Bryant Factory Authorized Dealer, Welzig Heating & Air consistently performs to strenuous standards of technical competence, business ethics, and customer approval.  Our team is NATE-certified, factory trained and regularly updated in progressive technology.  Equipped with leading edge equipment, tools, and a full inventory of genuine manufacturer’s replacement parts, we properly size and install new systems, accurately diagnose existing systems, and resolve the majority of issues right then and there.
Cleaning the debris that builds up on your filters will aid with the flow of air. When your air filter is clogged, your air handler must work harder to compensate for the blockage of air flow. In addition to driving up your utility bill, the reduced air flow through your heating and cooling system can cause your heat exchanger to overheat and shut off too quickly.    
Sometimes a heating and air conditioning system just needs to be repaired rather than completely replaced. You may need air conditioning repair services if there is leaking around the outside unit, the air coming into the house isn't hot or cool enough, the unit is short-cycling or constantly turning on and off, using the system is consistently resulting in higher-than-normal energy bills, or if there is excessive noise during startup and operation.
×