Heat pumps are similar to cooling only systems with one exception. A special valve in the refrigeration piping allow the refrigeration cycle to be operated in reverse. A cooling only system cools the indoor air and rejects heat to the outdoors. A heat pump can also cool the indoor air, but when the valve is reversed, the indoor air is heated. A supplementary electric resistance heater may also be used to assist the heat pump at lower outdoor temperatures. In colder climates, heat pumps require a defrost period. During defrost times the electric heater is the only means of heating the interior of the building. These units are manufactured as either split or packaged systems.
The performance of vapor compression refrigeration cycles[24] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[25]

Multiple inventions within this time frame preceded the beginnings of first comfort air conditioning system, which was designed in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Carrier equipped the Sacketts-Wilhems Printing Company with the process AC unit the same year. Coyne College was the first school to offer HVAC training in 1899.[12]
A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
BGE HOME HVAC repair technicians are thoroughly trained and certified to work on all major brands of heating and air conditioning equipment. When your system breaks down and needs a heating and air conditioning repair, you want to call someone you can trust. Need air conditioning service in the middle of the night? Emergency heating and cooling HVAC service is available 24 hours a day by calling 888-243-4663.
Trane central air conditioners are often billed as the “Cadillac of HVAC systems” and that’s because it’s one of the most reliable brands in the business. Trane AC is known for upholding warranties and offers a standard 10-year warranty that covers both parts and labor. Trane products are often pricier than other HVAC brands, but as the old saying goes, “You get what you pay for.”

As this liquid passes through the indoor cooling coil on the inside of the heat exchanger, two things happen to the air that passes over the coil’s surface on the outside of the heat exchanger. The air’s temperature is lowered (sensible cooling) and moisture in the air is removed (latent cooling) if the indoor air dew point is higher than the temperature of the coil’s surface. The total cooling (capacity) of an AC system is the sum of the sensible and latent cooling. Many factors influence the cooling capacity of a DX air conditioner. Total cooling is inversely proportional to outdoor temperature. As the outdoor temperature increases the total capacity is reduced. Air flow over the indoor cooling coil also affects the coil’s capacity and is directly proportional to the total capacity of an AC system. As air flow increases, the total capacity also increases. At higher air flow rates the latent capacity of the cooling coil is reduced. Indoor temperature and humidity also affect the total capacity of the AC system. As indoor temperatures increase, the sensible capacity also increases. Similarly, as indoor relative humidity increases the latent capacity of the AC system increases. Manufacturers of AC equipment typically provide a “performance map” of specific equipment to show how total, sensible, and latent capacity change with changing indoor and outdoor temperatures and humidity. Power consumption and energy efficiency are also provided in these charts.

Evaporative coolers, sometimes called "swamp coolers", do not have a compressor or condenser. Liquid water is evaporated on the cooling fins, releasing the vapor into the cooled area. Evaporating water absorbs a significant amount of heat, the latent heat of vaporisation, cooling the air. Humans and animals use the same mechanism to cool themselves by sweating.
When it comes to heater repair in Denver, a properly serviced system means significant savings for the homeowner. When a Denver heating technician inspects your system before the winter sets in, the first thing they will check is the condition of the air filters. These filters are important, because they are responsible for removing contaminants, allergens, and dust particles from the air every time the system is turned on. When the filters are clogged, expect more particles to easily pass through right into the air you breathe inside the home. The Denver heating experts will inspect and replace any filters that are no longer effective.
Service Experts Heating and Air Conditioning was built with the determination of delivering customers with the most excellent heating and cooling practices in the industry. Since its foundation, Donelson Air Service Experts in Nashville has been faithful to community, offering the first class HVAC (Heating, Ventilation, Air Conditioning) products and services in the area. If you are interested in more information about your regional HVAC leaders, give us a call at 615-953-9885 or set up an appointment with us online.
When it comes to saving money, using a free online coupon is a no-brainer. We offer these coupons to our customers who complete the online form to help reduce the cost of the service. Please note that the , the 30.00 off work performed coupon serves as an plumbing, HVAC and electrical coupon as well. Not many plumbing companies can boast that they also provide additional HVAC as well as Denver Electrical services, however at Brothers Plumbing, Heating and Electric – we do it all! It is important to call a professional when problems arise, and we will help you out every step of the way, including discounts!
"Had T.N. Bowes replace our whole HVAC system. What a difference it makes! Using less energy and it maintains the temperature inside the house like a champ, and it’s quiet! Had quotes from all the major HVAC players in the area and T.N. Bowes couldn’t be touched. One day install, polite workers and no mess to deal with when they left! Thanks, Eric, for getting us our new system!"

R407C is a zeotropic hydro-fluoro-carbon refrigerant and is a blend of difluoromethane (R32) providing the heat capacity, pentafluoroethane (R125) decreasing flammability and tetrafluoroethane (R134a) to reduce pressure. Difluoromethane serves to, pentafluoroethane andtetrafluoroethane. R407C was developed as a replacement for the ozone depleting R22.


SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
When your heating and cooling system stops working, you need the help of a reliable, experienced, local service professional that can diagnose the problem and repair your air conditioner or furnace at a fair price. You can count on The Home Depot's licensed and insured heating and cooling professionals for all your heaters, air conditioning units, and any ventilation needs.
×