Lennox was started to offer some of the most long-lasting, reliable HVAC systems in the market while providing the best service and quality for customers. Knoechel Heating Company in Zelienople is no different, with our on-going dedication to your comfort and commitment to the community. We strive to be the experts at what we do so you can always be comfortable, and know you can always count on us. Give us a call at 724-452-6280 or arrange an appointment with us so we can help you achieve whole home comfort. 
An air conditioner cools and dehumidifies the air as is passes over a cold coil surface. The indoor coil is an air-to-liquid heat exchanger with rows of tubes that pass the liquid through the coil. Finned surfaces connected to these tubes increase the overall surface area of the cold surface thereby increasing the heat transfer characteristics between the air passing over the coil and liquid passing through the coil. The type of liquid used depends on the system selected. Direct-expansion (DX) equipment uses refrigerant as the liquid medium. Chilled-water (CW) can also be used as a liquid medium. When the required temperature of a chilled water system is near the freezing point of water, freeze protection is added in the form of glycols or salts. Regardless of the liquid medium used, the liquid is delivered to the cooling coil at a cold temperature.
At Genz-Ryan, we are here for you 24 hours a day, 7 days a week so you can count on us for all your heating repair work in the Minneapolis area. Our furnace repair technicians are well-trained and experienced. They’re ready to take care of any heating issue that you may have. We are a Lennox Premier Furnace Dealer and provide expert furnace repair service for most of the Minneapolis/St. Paul area. For over 60 years we have been getting the job done right the first time.
Since 1994, Welzig Heating & Air has been providing professional air quality solutions throughout Boulder, Longmont, Louisville, Lafayette, CO & more. We specialize in industry leading products and employ skilled and knowledgeable technicians to do the job right the first time. As a family owned company, we understand how important the quality of your indoor environment can be on your health, comfort, and productivity. When you call the team from Welzig Heating & Air, you’ll enjoy helpful recommendations, convenient appointment times, and rewarding installation service that leaves you feeling refreshed.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).

This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.


Relative humidity is the ratio of the partial pressure of water vapour in an air-water mixture to the saturated vapour pressure of water at a prescribed temperature. In prevailing Northern European conditions relative humidity and percentage saturation (ration of moisture content) can be considered the same as the divergence is <1%.  In high temperature areas they should be treated differently as the divergence may be as high as 10%.
Its unique feature is the presence of one main external unit that connected to several indoor units. Such systems might be the right solution for maintaining the microclimate in several offices, shops, large living spaces. Just few of outdoor units do not worsen the aesthetic appearance of the building.The main external unit can be connected to several different indoor types: floor, ceiling, cassette, etc.
Multiple inventions within this time frame preceded the beginnings of first comfort air conditioning system, which was designed in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Carrier equipped the Sacketts-Wilhems Printing Company with the process AC unit the same year. Coyne College was the first school to offer HVAC training in 1899.[12]

The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.
Fresh-Aire UV is an innovation leader in the field of indoor air quality. Our award-winning UV light and carbon products fight mold, bacteria, viruses and odors in commercial and residential HVACR systems. Our products include Blue-Tube UV®, the world’s most popular germicidal UV light, the revolutionary APCO® PCO/carbon whole-house air purifier, and Mini UV the first UV light system designed specifically for mini-split AC systems.
If your furnace’s motor runs but the blower doesn’t move air, the belt that connects the two probably has broken. Replacing it is an easy fix. First, turn off all power to the unit and turn off the gas at the gas valve that serves the furnace. Remove the door on the front of the furnace cabinet to give you access to the blower (it might be on a slide-out drawer.) Check the number stamped on the belt and get an exact replacement from a home center or heating supply outlet.
The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.
We take great pride in our crew, choosing the best and brightest to represent R.S. Andrews in the face of an emergency. Our HVAC contractors boast not only unparalleled skill but also a friendly and professional demeanor. All of our work comes completely guaranteed, and we won’t rest until your emergency has been resolved to your full satisfaction!
Clean the condenser fan blades before the start of the cooling season. Brush any dust or debris off gently and then uncover the condenser coils, gently cleaning the dirty side. Then wrap the motor and other electrical components in plastic bags and gently spray from the inside with a hose. Now check the base pan under the unit and clear it out of any debris that has gathered.
Air conditioning is common in the US, with 88% of new single-family homes constructed in 2011 including air conditioning, ranging from 99% in the South to 62% in the West.[50] In Canada, air conditioning use varies by province. In 2013, 55% of Canadian households reported having an air conditioner, with high use in Manitoba (80%), Ontario (78%), Saskatchewan (67%), and Quebec (54%) and lower use in Prince Edward Island (23%), British Columbia (21%), and Newfoundland and Labrador (9%).[51] In Europe, home air conditioning is generally less common. Southern European countries such as Greece have seen a wide proliferation of home air-conditioning units in recent years.[52] In another southern European country, Malta, it is estimated that around 55% of households have an air conditioner installed.[53] In India AC sales have dropped by 40%[clarification needed] due to higher costs and stricter energy efficiency regulations.[54]
Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is rejected by the condenser which is located outside of room to be cooled.
The Rack Cooling Index (RCI) is a metric that measures the percentage of racks in the data centre where the air inlet temperature is at the recommended or allowable level under the guidelines put forth by ASHRAE. RCI (hi) is the metric for racks at the upper limit and RCI (lo) for racks at the lower limit. This metric reveals how uniformly and efficiently a data centre is being cooled.
Think Air Condition Parts when you need to replace virtually any type of heating and air conditioning equipment. We source any type of replacement air conditioning equipment from all manufacturers, and we can deliver them to you anywhere in the world! But that’s not the only benefit in ordering from Air Condition Parts. Because of our huge volume, we’re able to deliver the equipment you need at the best possible prices. Be sure to call Air Condition Parts for all your replacement air conditioning equipment needs and save on your next order!
Buy Home Air Conditioner - We also sell air conditioner equipment like AC condensers and heat pump condensers as well. Need a cased evaporator coil? No problem! Make sure to check out our full lines of trusted air conditioning products – and don't hesitate to contact us with any product-specific questions that may come up during the process of shopping for your new AC.
Wiring up the thermostat is usually pretty straightforward if an old one is being replaced. If a thermostat is being put in where one had never been before, that could involve running new wiring. The placement of the thermostat is also important so that its sensors can get an accurate reading of the temperature. A thermostat that is blocked by a bookcase or other large furniture will not get a good reading and will not perform efficiently.

Non fluorochemical refrigerants, such as ammonia (R717), carbon dioxide (R744) and hydrocarbons such as propane (R290) or isobutene (R600a). These products exist naturally in the environment. Alternative to fluorochemical refrigerants, often used due to their low direct GWP and ODP potential. (However it should be noted that commercial production of natural refrigerants is normally via man-made synthesis).
Bigger is not necessarily better when it comes to HVAC systems, and smaller isn't always more efficient. If you have too small of a system, your system will be running constantly as it tries to keep up with the temperature. If you have too large of a system, it won't run long enough to keep up with the humidity. In order to handle both temperature and humidity efficiently, an HVAC system should run for around 30 minutes at a time. If your system is staying on too long or shutting off after only around 10 minutes, you are not getting efficient performance.
Our team is NATE-certified.  North American Technician Excellence represents the entire HVAC industry and is an independent, third-party, non-profit organization.  NATE-certified technicians are skilled professionals who have verified real working knowledge of HVAC systems through specialized exams.  Whether your heating or cooling system requires routine maintenance or complex repair, the NATE-certified team from Nerthling's Heating and Air Conditioning shows up on time, prepared to complete the job quickly and accurately, without unnecessary multiple house calls.  We work on all makes and models and offer affordable and convenient service plans to protect your equipment from wear and tear, and ensure like-new performance.
Ventilating or ventilation (the V in HVAC) is the process of exchanging or replacing air in any space to provide high indoor air quality which involves temperature control, oxygen replenishment, and removal of moisture, odors, smoke, heat, dust, airborne bacteria, carbon dioxide, and other gases. Ventilation removes unpleasant smells and excessive moisture, introduces outside air, keeps interior building air circulating, and prevents stagnation of the interior air.
"Very impressed. Returned call within 24 hours. They came out the same day I spoke with them and made the repair within 25 minutes. Very low service call fee. I had another repair service out two weeks earlier and after 3 service calls and the central air still not fixed and temperatures in the high 90's, it was such a relief to have a company identify the problem, have the necessary part with them and fix the problem."
The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.
2Be sure the furnace’s circuit breaker is on or that its fuse has not blown. Check both the main electrical panel and any secondary subpanels that supply power to the unit. If the circuit has blown or tripped, reset the circuit breaker by flipping it all the way off and then on again. Or replace the fuse. If the circuit blows again, there is probably a short in the electrical system providing power to the furnace. For this, you may need to call an electrical contractor.
BGE HOME HVAC repair technicians are thoroughly trained and certified to work on all major brands of heating and air conditioning equipment. When your system breaks down and needs a heating and air conditioning repair, you want to call someone you can trust. Need air conditioning service in the middle of the night? Emergency heating and cooling HVAC service is available 24 hours a day by calling 888-243-4663.
If you're in need of heat repair, furnace repair or heating repair then call the Ashburn HVAC Services family-owned and operated HVAC contractor in Leesburg and Ashburn, VA. We owe all of our success to you, our Ashburn and Leesburg customers who support us and we want to thank you! The highest compliment we receive is the trust in your referral and we truly appreciate your support!
Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).
Bryant has been an industry leader of heating and cooling products for over a century. Innovative Bryant HVAC systems provide dependable solutions to home and commercial comfort and air quality. With everything from heat pumps to gas furnaces and air conditioning systems, Bryant has the products that offer leading-edge technology and precision engineering. Call us today to learn more!
The main problem when installing a multi-split system is the laying of long refrigerant lines for connecting the external unit to the internal ones. While installing a separate split system, workers try to locate both units opposite to each other, where the length of the line is minimal. Installing a multi-split system creates more difficulties, since some of indoor units can be located far from the outside. The first models of multi-split systems had one common control system that did not allow you to set the air conditioning individually for each room. However, now the market has a wide selection of multi-split systems, in which the functional characteristics of indoor units operate separately from each other.
Service Experts Heating and Air Conditioning was founded with the determination of delivering customers with the most excellent heating and cooling practices in the industry. Since its inception, A-PLUS Service Experts Heating & Air Conditioning in Waldorf has been devoted to our area, offering the first class HVAC (Heating, Ventilation, Air Conditioning) products and services in the area. If you would like to more information about your regional HVAC leaders, simply dial us at 301-747-3140 or set up an appointment with us using our online form.

An air handler contains the components that move the air throughout your home, called the blower. It is usually set inside the home and operates with both the heating and cooling components of your HVAC system. If you take a quick look at an air handler, it may closely resemble a furnace. Air handlers can run with an air conditioner and contains the indoor coil, used to cool and heat your home depending on which system it’s running with.
In modern buildings, the design, installation, and control systems of these functions are integrated into one or more HVAC systems. For very small buildings, contractors normally estimate the capacity and type of system needed and then design the system, selecting the appropriate refrigerant and various components needed. For larger buildings, building service designers, mechanical engineers, or building services engineers analyze, design, and specify the HVAC systems. Specialty mechanical contractors then fabricate and commission the systems. Building permits and code-compliance inspections of the installations are normally required for all sizes of building.
An air conditioner's compressor contains a refrigerant. As it works, it sends this refrigerant through the system. As warm air blows across the coil that carries this refrigerant, the heat transfers to the refrigerant (cool always absorbs warm). A fan moves the cooled air through the ducting and out of vents that lead into the rooms of your house. The refrigerant returns to the compressor where the absorbed heat is moved outside. The refrigerant is then sent through the coil once again to continue the cycle.

HVAC Repair

×