Service Experts Heating and Air Conditioning was founded on the basis of providing customers with the best heating and cooling practices in the industry. Since its inception, Service Experts has been dedicated to community, providing the top of the line HVAC products and services in your area. If you want more information about your local HVAC leaders, call us at 866-397-3787 or set up an appointment with us online.
Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.
An air conditioner cools and dehumidifies the air as is passes over a cold coil surface. The indoor coil is an air-to-liquid heat exchanger with rows of tubes that pass the liquid through the coil. Finned surfaces connected to these tubes increase the overall surface area of the cold surface thereby increasing the heat transfer characteristics between the air passing over the coil and liquid passing through the coil. The type of liquid used depends on the system selected. Direct-expansion (DX) equipment uses refrigerant as the liquid medium. Chilled-water (CW) can also be used as a liquid medium. When the required temperature of a chilled water system is near the freezing point of water, freeze protection is added in the form of glycols or salts. Regardless of the liquid medium used, the liquid is delivered to the cooling coil at a cold temperature.
Wiring up the thermostat is usually pretty straightforward if an old one is being replaced. If a thermostat is being put in where one had never been before, that could involve running new wiring. The placement of the thermostat is also important so that its sensors can get an accurate reading of the temperature. A thermostat that is blocked by a bookcase or other large furniture will not get a good reading and will not perform efficiently.
Another precaution you can take to prolong the life of your central air unit is to cover it up during winter. Protect it from ice and snow by putting a sheet of plastic or wood on top of the unit. However, only cover the top and not the whole machine. You don't want to trap moisture that could cause it to rust and you don't want to provide a hiding spot for pests.
It’s important to keep your furnace receives regular maintenance to ensure that it’s working properly and efficiently. Routine maintenance can also extend the life of your heating system by several years. Ask about our annual maintenance agreements that cover your plumbing, heating, and cooling systems and save you money. A furnace that has been neglected may be working too hard, which can result in inconsistent air temperatures in your Minneapolis area home. Learn more about the importance of routine maintenance on your HVAC system.
We came home to a gas leak and our CO detector going off last Thursday (was very cold out)! After contacting Natl Fuel we proceeded to call Nerthlings for help! They arrived quickly, found the problem & worked with us to install our new furnace the next day. They were great to deal with & a huge help with the bad weather we were having at the time!
An important component of natural ventilation is air change rate or air changes per hour: the hourly rate of ventilation divided by the volume of the space. For example, six air changes per hour means an amount of new air, equal to the volume of the space, is added every ten minutes. For human comfort, a minimum of four air changes per hour is typical, though warehouses might have only two. Too high of an air change rate may be uncomfortable, akin to a wind tunnel which have thousands of changes per hour. The highest air change rates are for crowded spaces, bars, night clubs, commercial kitchens at around 30 to 50 air changes per hour.[17]
Think Air Condition Parts when you need to replace virtually any type of heating and air conditioning equipment. We source any type of replacement air conditioning equipment from all manufacturers, and we can deliver them to you anywhere in the world! But that’s not the only benefit in ordering from Air Condition Parts. Because of our huge volume, we’re able to deliver the equipment you need at the best possible prices. Be sure to call Air Condition Parts for all your replacement air conditioning equipment needs and save on your next order!
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.
Aurora residents are well aware that when the furnace goes out in their home, can be incredibly frustrating to get working again. At times, there are serious things that go wrong with a home that needs to get fixed very quickly. As far as the furnace goes, it needs to get repaired or fixed as soon as possible, which is why it’s good to know that our furnace repair company does furnace replacement in Aurora and also Aurora furnace repair, is prepared to help at any time. To learn more about our furnace and heating services, click HERE today!
Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[28]
Once warm air inside your home blows across the indoor evaporator coil, its heat energy transfers to the refrigerant inside the coil. That transfer, in turn, “cools” the air. The refrigerant is pumped back to the compressor where the cycle begins again. The heat absorbed by the refrigerant is moved outside your home while cooled air is blown inside. Moisture that contributes to humidity is also condensed out of the air. Your cooling system is usually combined with your central heating system because they share the same ductwork for distributing conditioned air throughout your home.
This is a great option for cooling your home or business without having to deal with the ductwork.  Other systems require ductwork so that the cool air can travel throughout the space.  A ductless mini split air condition doesn’t require ductwork because it has an air conditioner or a heat pump outside that connects to units in the home that handle the cooling being pushed into them from outside.  You can control the temperature of a whole home or just one room by controlling the air handlers in each specific area.  This allows for more control and a more efficient way to control the temperature and cost of operating the ductless mini split air conditioner.
If your furnace has a pilot light, look for the flame. Check your owner’s manual or the instructions posted inside the furnace cabinet for step-by-step lighting instructions. Usually this involves first turning the gas valve to Off and waiting a couple of minutes. Then you turn it to Pilot. Next, press and hold it down while you light the flame. Last, wait a minute or so, release it, and then turn it to On.
Established in 1988, T. N. Bowes Heating & Air Conditioning, Inc. provides a trusted source of new installation, replacement, seasonal maintenance, and prompt repair of heating, cooling, and air quality equipment in Leonardtown, Waldorf, Lusby, La Plata, St. Leonard, California, Prince Frederick, Hughesville & Hollywood, MD. As a Carrier Factory Authorized Dealer, our team is fully licensed, extensively trained, and consistently updated in a wide range of industry-leading options to meet any challenge. All projects are handled to your specifications and completed within a strict timetable.
A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.
This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.
Smyrna homes and businesses have relied on Coolray for air conditioning service and installation since 1966. We can provide repair and maintenance on all makes and models of air conditioners for your home or business and offer 24 hour emergency AC repair service. We also offer a wide range of new air conditioning systems and our expert air conditioning technicians can help you select an air conditioner or heat pump that is right for your home and budget.
Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]

Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.


As a Leesburg and Ashburn AC repair company, we offer emergency and routine AC repair services to the residents and commercial companies in Leesburg and Ashburn, Virginia. We're professional, prompt and punctual. Please call us immediately for your your repair needs. Operators are standing by to take your call. We also encourage you to read our reviews on our Google page.

Over the Labor Day weekend our hot water heater decided it was time to say good bye. Since we had our fall check the week before, we called Nerthlings. I cannot say enough good things about how this situation was handled. The technician, Dwain, was knowledgeable, friendly, and quite helpful without being pushy. Our questions were answered clearly. I am never made to feel that this is something...
As one of the premier heating & cooling companies in St. Louis, Vogel has dedicated our business to serving our customers with the utmost quality in HVAC services for both residential and commercial entities alike. We strive to build out a culture within our team that delivers the kind of experience you deserve when working with a service provider. The qualities that are most important to you, are most important to us - convenience, trustworthiness, good value, impeccable quality, and our willingness to stand behind our successes and learn from our mistakes. We invite you to explore our site, see what customers say, and give us a call.
Don’t forget, when you’re in the need for 24 HR emergency repair in Akron, Ohio, Jennings is there for you no matter the time of day or night—24 hours a day and 7 days a week. If you have an emergency, please call 330-784-1286 now. If you would like to request service, please fill out and submit the form below and a Jennings associate will be in touch make an appointment.

The 2nd-century Chinese mechanical engineer and inventor Ding Huan of the Han Dynasty invented a rotary fan for air conditioning, with seven wheels 3 m (10 ft) in diameter and manually powered by prisoners of the time.[6] In 747, Emperor Xuanzong (r. 712–762) of the Tang Dynasty (618–907) had the Cool Hall (Liang Dian 涼殿) built in the imperial palace, which the Tang Yulin describes as having water-powered fan wheels for air conditioning as well as rising jet streams of water from fountains. During the subsequent Song Dynasty (960–1279), written sources mentioned the air conditioning rotary fan as even more widely used.[7]
*Residential Service call's subject to $119.00 travel and diagnostic fee, Commercial Service call's subject to a $149.00 travel and diagnostic fee. Once diagnosed, necessary repairs will be quoted in accordance with standard flat rate repair price. Repair and quoted repair price may be accepted or declined by the customer at that time. Travel and Diagnostic fee will still apply in case customer declines repair. All calls are C.O.D. Overtime rates for Residential Service are $169.00, overtime rates for Commercial services are $179.00.  These rates are for services performed after normal business hours Monday through Friday 8am-4:30pm.
×