Strongsville Heating & Air Conditioning simplifies the challenges of keeping a perfectly comfortable home. We provide convenience, cost-savings, and reliability using top of the line products, premium materials, highly skilled technicians and exceptional customer service. Whether you need a new heating/cooling installation, replacement, retrofit, routine maintenance, trustworthy repair or air quality options, count on our team of NATE-certified technicians to eliminate stress and maximize comfort. We protect your busy schedule with flexible appointments, prompt arrival and mess free completion. Strongsville Heating & Air Conditioning is always available to you for Emergency Service, 24 hours a day, 365 days a year across Strongsville & Surrounding Areas.


This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.
Since 1994, Welzig Heating & Air has been providing professional air quality solutions throughout Boulder, Longmont, Louisville, Lafayette, CO & more. We specialize in industry leading products and employ skilled and knowledgeable technicians to do the job right the first time. As a family owned company, we understand how important the quality of your indoor environment can be on your health, comfort, and productivity. When you call the team from Welzig Heating & Air, you’ll enjoy helpful recommendations, convenient appointment times, and rewarding installation service that leaves you feeling refreshed.
Cold aisle is a layout design for server racks and other computing equipment in a data centre. Cold aisle data center design involves lining up server racks in alternating rows with cold air intakes facing one way and hot air exhausts facing the other. The rows composed of rack fronts are called cold aisles. See Data Centre Aisle Containment for more information.
Tired of dealing with an inoperable furnace? Or, maybe your heating system is only heating half the rooms in your home? Whether you need a new heating system installed or an existing unit repaired, there’s only one name to know—ABC Plumbing, Heating, Cooling & Electric. With more than six decades of experience handling Chicago’s heating problems, our team at ABC has the experience and know-how to get any heating issue diagnosed and resolved quickly and efficiently.

The use of CFC as a refrigerant was once common, including the refrigerants R-11 and R-12 (sold under the brand name Freon-12). Freon refrigerants were commonly used during the 20th century in air conditioners due to their superior stability and safety properties. When they are released accidentally or deliberately, these chlorine-bearing refrigerants eventually reach the upper atmosphere.[60] Once the refrigerant reaches the stratosphere, UV radiation from the Sun homolytically cleaves the chlorine-carbon bond, yielding a chlorine radical. These chlorine radicals catalyze the breakdown of ozone into diatomic oxygen, depleting the ozone layer that shields the Earth's surface from strong UV radiation. Each chlorine radical remains active as a catalyst until it binds with another radical, forming a stable molecule and quenching the chain reaction.
Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).
Have your contractor do a load calculation based on a recognized method, such as one in Manual J from the ACCA. The contractor’s evaluation should include whether your ducts need to be resized, sealed and insulated, or replaced. Remember that an indoor evaporator coil and outdoor condenser must be a matched set from the same brand, or the performance, efficiency, and capacity might not meet expectations.
Without proper ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%). However, at several hundred ppm, carbon monoxide exposure induces headaches, fatigue, nausea, and vomiting. Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood's ability to transport oxygen. The primary health concerns associated with carbon monoxide exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also trigger heart attacks. Neurologically, carbon monoxide exposure reduces hand to eye coordination, vigilance, and continuous performance. It can also affect time discrimination.[15]