A mini-split system typically supplies air conditioned and heated air to a single or a few rooms of a building.[38] Multi-zone systems are a common application of ductless systems and allow up to 8 rooms (zones) to be conditioned from a single outdoor unit. Multi-zone systems typically offer a variety of indoor unit styles including wall-mounted, ceiling-mounted, ceiling recessed, and horizontal ducted. Mini-split systems typically produce 9,000 to 36,000 Btu (9,500–38,000 kJ) per hour of cooling. Multi-zone systems provide extended cooling and heating capacity up to 60,000 Btu's.
Just had a well knowledge maintenance tech from A-OK come out and maintenance my AC unit and furnace. He informed me about all my safety’s were working properly and my Freon was well charged, cleaned my coils and drain, replaced my filter and checked the temps in all my supply’s. This young mans name was Mike and I would recommend him to come out to all my friends and family’s homes for maintenance.
Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation
A gas that can be retrofitted into a refrigeration system designed for another, without major system changes. For example, R422D is a drop-in replacement for R22 in many applications. However, hydrocarbon refrigerants are NOT drop-in alternatives for most fluorocarbon refrigerants due to substantial system changes needed to manage their differing characteristics (e.g. flammability).

An air handler contains the components that move the air throughout your home, called the blower. It is usually set inside the home and operates with both the heating and cooling components of your HVAC system. If you take a quick look at an air handler, it may closely resemble a furnace. Air handlers can run with an air conditioner and contains the indoor coil, used to cool and heat your home depending on which system it’s running with.

Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).
A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
When our Denver heating company provides you with maintenance checks before the cold of winter sets in, you will be saving money in several different ways. One of the benefits of a maintenance plan is our technicians will be less likely to have to make repairs throughout the year as long as the system is properly maintained. Our Denver heating company will have your system running at its most efficient, helping to reduce your utility bills each month. An added benefit of a more efficiently running system is the positive environmental effect that it will have.
In the refrigeration cycle, heat is transported from a colder location to a hotter area. As heat would naturally flow in the opposite direction, work is required to achieve this. A refrigerator is an example of such a system, as it transports the heat out of the interior and into its environment. The refrigerant is used as the medium which absorbs and removes heat from the space to be cooled and subsequently ejects that heat elsewhere.
The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.
Window unit air conditioners are installed in an open window. The interior air is cooled as a fan blows it over the evaporator. On the exterior the heat drawn from the interior is dissipated into the environment as a second fan blows outside air over the condenser. A large house or building may have several such units, allowing each room to be cooled separately.
Has another company told you that your furnace has a cracked heat exchanger?  The heat exchanger is the heart of your furnace. Its failure can result in a dangerous situation for your home and the best solution is usually a new furnace.  Because of these issues, Bonney takes this situation very seriously.  We will offer you proof of the cracked heat exchanger in the form of a picture from our video inspection camera or a report from our exhaust gas analyzer, before we make our recommendation.
Here at Brothers Plumbing, Heating, and Electric, we have a Home Care Club that provides members with many benefits. These benefits include: 2 year warranty on all work (drain work is excluded), transferable club membership, no “show up” fees, priority service, 10% discount on repairs, quarterly newsletters, carefree scheduling (we will contact you and remind you when you need service), 2 free furnace/air conditioner filter changes, exclusive coupons, quarterly drawings, 4 on-going safety checks, and a 100% satisfaction guarantee. So if you’d like to join our Home Care Club, then give us a call or click here today.

Refrigerant 22 (R-22 or MonoChloroDiFlouroMethane, CHClF2) is one of the most common refrigerants and is used in a wide variety of applications such as refrigeration, aerosol propellants, cleaning solvents, and foaming agents for plastics. This refrigerant is believed to be partially responsible for damaging the earth’s ozone layer and it’s use is being phased out over the next two decades. The ozone layer is a result of sunlight reacting with oxygen to produce a layer in the stratosphere more than 10 km above the earth’s surface. As R-22 refrigerant escapes from an AC system through leaks or is released into the atmosphere by other means, the R-22 molecule containing the chlorine atom (“monochloro”) rises in the atmosphere. Sunlight breaks down the R-22 molecule to yield a free chlorine radical (Cl-). The free chlorine radical combines with ozone (O3), decomposing it into normal oxygen (O2).

Bonney’s NATE certified technicians will troubleshoot and repair your furnace for safe and reliable operation. Our technicians use state of the art tools including video inspection cameras and exhaust gas analyzers to perform thorough, comprehensive diagnostics when equipment is broken. Furthermore, we arrive in a “warehouse on wheels” stocked with many parts to get your furnace repaired as quickly as possible.  For an unexpected heater repair Bonney offers financing to make your comfort affordable.
A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.

Sometimes a heating and air conditioning system just needs to be repaired rather than completely replaced. You may need air conditioning repair services if there is leaking around the outside unit, the air coming into the house isn't hot or cool enough, the unit is short-cycling or constantly turning on and off, using the system is consistently resulting in higher-than-normal energy bills, or if there is excessive noise during startup and operation.

×