"The estimator and install crew from TN Bowes get 5 stars from me. Everyone was friendly and professional, and the attention to detail was evident throughout the job. The crew stayed onsite until they were sure that the system was functioning, and everything was cleaned up well. I will continue to refer friends and family to TN Bowes for all their HVAC needs!"


In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.
Sky Heating & Air Conditioning answers any comfort challenge with straightforward, satisfying solutions. We get rid of the need for labor-intensive renovation. We don’t tear down walls or ceilings, steal precious closet space for the installation of ductwork, or cause mess or damage. With the installation of a ductless HVAC system, we answer your temperature control requirements with wonderful simplicity.

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).


Vredevoogd Heating & Cooling Grand Rapids MI routinely serves the areas of Grand Rapids, Wyoming, Lansing, Grandville, and Kalamazoo. We provide a comprehensive menu of HVAC services delivered by certified HVAC technicians who specialize in heating and cooling repair and installation. World-class customer service is a cornerstone of our business and we are committed to doing the job right the first time. We have a reputation for integrity and service excellence. By living up to our good name, we continue to build our customer base throughout the Michigan region and look forward to adding you to our service family. So if you are looking for a “heating & air company near me” in Grand Rapids, or a Furnace Repair Lansing, Furnace Repair Kalamazoo and more. Call today.
Buy Home Air Conditioner - We also sell air conditioner equipment like AC condensers and heat pump condensers as well. Need a cased evaporator coil? No problem! Make sure to check out our full lines of trusted air conditioning products – and don't hesitate to contact us with any product-specific questions that may come up during the process of shopping for your new AC.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
Without proper ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%). However, at several hundred ppm, carbon monoxide exposure induces headaches, fatigue, nausea, and vomiting. Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood's ability to transport oxygen. The primary health concerns associated with carbon monoxide exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also trigger heart attacks. Neurologically, carbon monoxide exposure reduces hand to eye coordination, vigilance, and continuous performance. It can also affect time discrimination.[15] 

Heating Repair Co

×