In order to make your everyday life easier and more enjoyable, Sky Heating & Air Conditioning specializes in state-of-the-art heating and cooling technology, partnering with Trane, Mitsubishi, and Waterfurnace.  We bring you HVAC solutions that represent the best the industry has to offer, ensuring long-term performance and satisfaction.  Whether you’re looking for the design/build of a new system, replacement, or hoping to cut costs and enhance convenience, we answer with proven products.  Our qualified HVAC technicians help you determine the ideal solution for your exact requirements, and make sure you’re happy with every step of the process.  From ductless HVAC to geothermal heating and cooling systems, we offer a wide selection of options and comprehensive services to answer any type of challenge.  Call on Sky Heating & Air Conditioning and let us exceed your expectations today!
A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.
A number of other variables can influence your decision on whether to repair or replace your furnace, as well. In addition to cost and brand, consider the expected lifetime of your furnace. If it is more than 15 years old, it might make more sense to invest in a new unit even if it costs more than simply repairing the current problem. Long-term costs also play into the equation. For example, your new furnace may be more energy efficient than the current unit. Even though you will pay more for the actual installation, you might be able to make back your investment through lower energy bills. To make your decision, consult with a reliable professional on what to do. In inspecting your furnace, they will be able to make an informed recommendation that looks not just to the next year, but years into the future. That way, you can make the best possible decision for your home and budget long-term.
Absorption heat pumps are a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. An absorption pump dissolves ammonia gas in water, which gives off heat. Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, which absorbs heat from the outdoor air.[citation needed]
Not only is it good to rake up leaves to protect your lawn's grass, it's also beneficial for your air conditioner. Rake leaves, cut grass and trim back any tree branches around the unit as a preventative measure. All this yard debris could end up blocking the fins or other parts of the system and cause your AC to use more power to generate cool air in your home.
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.

This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.
Hi, I'm not sure if this is a question. Are you trying to get a smoother finish when painting with a roller? If so, please be aware that rollers are made with a variety of different kinds of nap. Those with very short nap are designed for smoother walls. Talk with your paint dealer about the surface you're painting and the right roller (and paint) for the job.
Clean the condenser fan blades before the start of the cooling season. Brush any dust or debris off gently and then uncover the condenser coils, gently cleaning the dirty side. Then wrap the motor and other electrical components in plastic bags and gently spray from the inside with a hose. Now check the base pan under the unit and clear it out of any debris that has gathered.
In the event of an emergency with your residential heating and cooling system, we understand that you simply cannot wait! At R.S. Andrews, we take your comfort and well-being seriously and are proud to offer our emergency HVAC repair at any hour, on any day—including weekends! We provide only the highest quality services to ensure your needs are met!
Cold aisle is a layout design for server racks and other computing equipment in a data centre. Cold aisle data center design involves lining up server racks in alternating rows with cold air intakes facing one way and hot air exhausts facing the other. The rows composed of rack fronts are called cold aisles. See Data Centre Aisle Containment for more information.
Buy Home Air Conditioner - We also sell air conditioner equipment like AC condensers and heat pump condensers as well. Need a cased evaporator coil? No problem! Make sure to check out our full lines of trusted air conditioning products – and don't hesitate to contact us with any product-specific questions that may come up during the process of shopping for your new AC.
Just had a well knowledge maintenance tech from A-OK come out and maintenance my AC unit and furnace. He informed me about all my safety’s were working properly and my Freon was well charged, cleaned my coils and drain, replaced my filter and checked the temps in all my supply’s. This young mans name was Mike and I would recommend him to come out to all my friends and family’s homes for maintenance.

If you find yourself with a need today, don’t hesitate to contact us now. We want to prove to you why we have such stellar ratings for quality and customer satisfaction in Cary. To easily make an appointment, you can contact us on our website, chat online, or call us at 919-578-4329. With one conversation, we’ll show you why you can be comfortable and confident in your decision to work with us. Find out today what your friends and neighbors in Cary have already found: You can rely on Service Experts.
For more than sixty years, Nerthling's Heating and Air Conditioning has continued a tradition of superior customer service across Erie County, including Erie, Millcreek and Fairview.  Family owned and operated, we treat you, your home, and your comfort the way we would like to be treated.  This commitment to integrity extends to every service and product we provide.  Our goal is to deliver the highest rewards for your investment, whether you require installation, maintenance, or repair.  We offer a wide range of styles and sizes of equipment, services, and resources to help you achieve your goals for temperature control, air quality, and energy savings.
Heat pumps are similar to cooling only systems with one exception. A special valve in the refrigeration piping allow the refrigeration cycle to be operated in reverse. A cooling only system cools the indoor air and rejects heat to the outdoors. A heat pump can also cool the indoor air, but when the valve is reversed, the indoor air is heated. A supplementary electric resistance heater may also be used to assist the heat pump at lower outdoor temperatures. In colder climates, heat pumps require a defrost period. During defrost times the electric heater is the only means of heating the interior of the building. These units are manufactured as either split or packaged systems.
Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).

The warm air inside your home is drawn into the system through return ducts and then go over a refrigerant coil. As the warm air is blown across the cooled coil, heat is removed. Refrigerant lines then carry the heat outside. Now you’re left with cool, comfortable indoor air that you can enjoy on the hottest of days. And that’s pretty much it. Sure, the equipment is more complex than that, but the process itself is easy to break down and comprehend.
Demand controlled kitchen ventilation (DCKV) is a building controls approach of slowing down kitchen exhaust fans and subsequent supply air in response to the actual cooking loads in a commercial kitchen. Traditional commercial kitchen ventilation systems operate at 100% fan speed independent of the volume of cooking activity and DCKV technology changes that to provide significant fan energy and conditioned air savings. By deploying smart sensing technology, both the exhaust and supply fans can be controlled to capitalize on the Law of Affinity for motor energy savings, reduce makeup air heating and cooling energy, increasing safety and reducing ambient kitchen noise levels.[27]
Architectural acoustics Architectural engineering Architectural technologist Building services engineering Building information modeling (BIM) Deep energy retrofit Duct leakage testing Environmental engineering Hydronic balancing Kitchen exhaust cleaning Mechanical engineering Mechanical, electrical, and plumbing Mold growth, assessment, and remediation Refrigerant reclamation Testing, adjusting, balancing
By combining immediate results with sustainable performance, we protect the value of your investment.  We provide skilled installation, maintenance, and repair of gas furnaces, heat pumps, dual fuel systems, boilers, air conditioners, air quality products, traditional and tankless water heaters, and advanced duct cleaning services.  Welzig Heating & Air is the right choice for  the comfort, safety, and health of homes or offices across Boulder, Longmont, Louisville, Lafayette, CO & more.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
The re-processing and upgrading of refrigerant by filtering, drying, distillation and sometimes chemical treatment of the recovered refrigerant. The re-processed substance will require laboratory analysis to verify that it meets a specific quality standard, normally that of new refrigerant. This normally involves processing “off-site” at a re-processing or a refrigerant manufacturing facility.
Its unique feature is the presence of one main external unit that connected to several indoor units. Such systems might be the right solution for maintaining the microclimate in several offices, shops, large living spaces. Just few of outdoor units do not worsen the aesthetic appearance of the building.The main external unit can be connected to several different indoor types: floor, ceiling, cassette, etc.

Furnace Repair

×